Switchgear
Hyundai Electric manufactures high-performance, high-reliability based on IEC and ANSI certified switchgear and has the largest supply record in the domestic industrial plant market, ranging from various types of buildings to plants, including nuclear power plants.
We manufacture various types of switchgear including gas-insulated switchgear cubicles, gas-insulated switchgear units, high/low-voltage switchgear, motor control panels, etc. with key features such as customizable designs, long lifetime, and minimal maintenance requirements.
Product features
- High reliability and arc safety
- Long lifetime and minimal maintenance requirements
- Compact and customizable optimized design
- Standardized design for high compatibility
- Extensive supply record
- Minimisation of Maintenance
long lifetime and minimal maintenance requirements - Flexibility of Plan
Compact and customizable optimized design - Quality Reliability
Extensive supply record
Gallery
Product specifications
Image | Spec | C-GIS | |||
---|---|---|---|---|---|
Model name | HMGS-G11 | HMGS-G30 | HMGS-G81 | HMGS-G82 | |
Applicable standards | IEC 62271-200 | IEEE C37.100 | |||
Rated voltage | ~24kV | ~36kV | ~36(40.5kV) | ~38kV | |
Rated current | ~2000A | ~2000A | ~4000A | ~2500A | |
Breaking capacity | 25kA/3s | 31.5kA/3s | 40kA/3s | 40kA/3s |
Image | Spec | RMU | ||||
---|---|---|---|---|---|---|
Model name |
HRS-LLF | HRS-LLF | HRS-L (LBS) |
HRS-F (Fused LBS) |
HRS-V (CB) |
|
Applicable standards |
IEC62271-200 | |||||
Rated voltage |
24/12kV | 7.2/12kV | ||||
Rated current |
200A | 630A | 630A | 630A | 630A | |
Breaking capacity |
21kA/3s | 21kA/3s | 20kA/3s | 20kA/3s | 20kA/3s |
Spec | 36/38kV | |
---|---|---|
Model name | HMS-N36 | HMS-A38 |
Applicable standards |
IEC 62271-200 | ANSI/IEEE C37.20.2 |
Rated voltage | 36kV | 38kV |
Rated current | 1,250/2,000/2,500/3,150A | 1,200/2,000/3,000A |
Breaking capacity |
~ 31.5kA/3s | ~ 40kA/3s |
Features | - | - |
Image |
Spec | 24kV |
---|---|
Model name | HMS-N24 |
Applicable standards |
IEC 62271-200 |
Rated voltage | 24kV |
Rated current | 1,250/2,000/2,500/3,150A |
Breaking capacity |
~ 31.5kA/3s |
Features | Miniature |
Image |
Spec | 17.5kV | ||
---|---|---|---|
Model name | HMS-N17.5 | HMS-N17.5C | HMS-A15 |
Applicable standards |
IEC 62271-200 | IEC 62271-200 | ANSI/IEEE C37.20.2 |
Rated voltage | 17.5kV | 17.5kV | 15kV |
Rated current | 1,250/2,000/3,150/4,000A | 1,250/2,000/3,150/4,000A | 1,200/2,000/3,000A |
Breaking capacity |
~ 40kA/3s | ~ 50kA/3s | ~ 40kA/3s |
Features | General | Miniature | Two-phase load |
Image |
Spec | 12kV | |
---|---|---|
Model name | HMS-N12 | HMS-N12C |
Applicable standards |
IEC 62271-200 | |
Rated voltage | 12kV | |
Rated current | 1,250/2,000/3,150/4,000A | 1,250/2,000/3,150/4,000A |
Breaking capacity |
~ 50kA/3s | ~ 50kA/3s |
Features | - | Miniature |
Image |
Spec | 7.2kV 이하 | ||
---|---|---|---|
Model name | HMS-N7.2 | HMS-N7.2D | HMS-A5 |
Applicable standards |
IEC 62271-200 | ANSI/IEEE C37.20.2 | |
Rated voltage | 7.2kV | 4.76kV | |
Rated current | 1,250/2,000/3,150/4,000A | 1,250/2,500A | 1,200/2,000/3,000A |
Breaking capacity |
~ 50kA/3s | ~ 40kA/3s | ~ 50kA/3s |
Features | - | - | Two-phase load |
Image |
Image | Spec | MV SWGR for Nuclear | |
---|---|---|---|
Model name | HMS-112 | ||
Applicable standards |
ANSI/IEEE C37.20.2 | ||
Rated voltage | 15kV | 4.76kV | |
Rated current | 1,200/2,000/3,000A | 1,200/2,000/ 3,000/4,000A |
|
Breaking capacity |
~ 40kA/3s | ~ 50kA/3s | |
Features | Two-phase load | Two-phase load |
Spec | Basic Switchgear(Metal-Enclosed) | multi-panel MCC | Load Center |
---|---|---|---|
Model name | HLS-LV | H8PU-L1 | HLS-LC |
Applicable standards |
IEC 60439, 60144 | IEC 60439, 60144 | ANSI C37.20.1, C37.50 & C37.51 |
Rated voltage | ~ 660V, 50 to 60Hz | ~ 660V, 50 to 60Hz | ~ 440V, 50/60Hz |
Rated current | ~ 5,000A | ~ 4,000A | 800/1,600/2,000/3,000/4,000A |
Breaking capacity | ~ 85kA/1s | ~ 80kA/1s | ~ 50kA/1s |
Features | Three-phase loadable | Two-phase loadable | Three-phase loadable |
Image |
Spec | Motor Control Panel(MCP) | ||
---|---|---|---|
Model name | HiMCC | H8PU-S1 | H5600 |
Applicable standards |
IEC 61439-1.2 | IEC 60439, 60144 | ANSI C37.20.1/NEMA ICS 2-322 |
Rated voltage | ~ 690V 50/60Hz | ~ 660V, 50 to 60Hz | ~ 660V |
Rated current | ~ 5,000A | ~ 4,000A | ~ 3,000A |
Breaking capacity |
up to 100kA/1s | ~ 80kA/1s | ~ 100kA/1s |
Features | Max. 20 Unit applicable per panel | Arrangement with LV Switchgear is applicable | 1 Panel Max 6 unit |
Image |
Image | BUSDUCT | |||||
---|---|---|---|---|---|---|
Nominal voltage(V) |
Rated continuous current(A) |
short time current(A) |
insulation voltage(kV) | conductor temperature increase (given tambient temperature tof 40°C)(℃) |
||
power- tfrequency twithstand tvoltage |
impulse tvoltage |
|||||
690 | 600 ~ 1,600 2,000 ~ 3,000 4,000 ~ 5,000 |
75 ~ 150 | 2.2 | - | 65 | |
7,200 | 1,200 ~ 4,000 | 19 ~ 78 | 20 | 60 | 65 | |
12,000 | 1,200 ~ 4,000 | 19 ~ 78 | 28 | 75 | 65 | |
17,500 | 1,200 ~ 4,000 | 19 ~ 78 | 36 | 95 | 65 | |
24,000 | 1,200 ~ 4,000 | 19 ~ 78 | 50 | 125 | 65 | |
36,000 | 2,000 ~ 3,000 | 58 | 75 | 170 | 65 |
Image | BUSWAY | |
---|---|---|
Rated voltage | AC690V | |
Rated current | 600 ~ 5,000A | |
Phase & Wire | 3P3W, 3P4W, 1P3W | |
Frequency | 50/60Hz |
Standards and Certification
Our switchboards are IEC and ANSI certified (standards 62271, 61439, 60947, etc.) by highly accredited international certified testing agencies (KEMA, CESI, KERI, etc.). In addition, they are certified under standards of various other countries such as GOST-R, TRCU, LAPEM, etc.
KEMA
|
CESI
|
KERI
|
IEC
|
GOST-R
|
TRCU
|
LAPEM
|